Pump Manifold

3-Way Valve for Microfluidic Pumps

 
flow splitter_3-way valve.png
Syringe automatic refilling.png
modular.png
flow rate.png

3-WAY VALVE SWITCHING: Switch between 3 different outlets with switching time of ~30ms.

AUTOMATIC SYRINGE RECHARGING / REFILLING

COMPATIBLE WITH EXIGO SYRINGE PUMP & UNIGO PRESSURE PUMP

PRESSURE RANGE: up to 2 bar.

how-does-it-work.png

HOW DOES IT WORK?

The pump manifold has one inlet, which is connected to the ExiGo or UniGo pump and a 3-way switching valve giving you the option of pumping the fluid into one of three outlets which may be connected to a microfluidic chip or sample reservoirs.  This provides you with many options:

  • Automatic refilling / recharging of syringe for ExiGo syringe pump.

  • Injection of reagents in multiple channels at different times.
Pump Manifold_How does it work.png

DOWNLOADS

Experimental Set-ups

Automatic refilling / recharging of syringe for ExiGo syringe pump.

  • Connect valve #1 to sample reservoir #1
  • Connect valve #2 to sample reservoir #2
  • Connect valve #3 to flow sensor and microfluidic chip.
  • Use SmartFlo program for PC to define the refill speed of sample reservoirs: provides user with many options, e.g. using one sample reservoir as a wash solution.

Schematic of Pump Manifold in Experimental Set-up
Schematic of Pump Manifold in Experimental Set-up

Connecting pump manifold to ExiGo syringe pump for automatic refilling of syringe via sample #1 or sample #2

press to zoom
ExiGo pump connected to Pump Manifold
ExiGo pump connected to Pump Manifold

press to zoom
Experimental Set-up for Automatic Syringe refill
Experimental Set-up for Automatic Syringe refill

press to zoom
Schematic of Pump Manifold in Experimental Set-up
Schematic of Pump Manifold in Experimental Set-up

Connecting pump manifold to ExiGo syringe pump for automatic refilling of syringe via sample #1 or sample #2

press to zoom
1/3

SmartFlo program for PC:

Simple commands for defining refilling speed.

Pump Manifold: Define settings
Pump Manifold: Define settings

1. In the Manual window, click the Valve icon.

press to zoom
Pump Manifold: Define valve settings
Pump Manifold: Define valve settings

2. Select the output valve (one of three available channels). Click Next.

press to zoom
Pump Manifold: Define refill settings
Pump Manifold: Define refill settings

4. Select the refill speed. Click the green tick.

press to zoom
Pump Manifold: Define settings
Pump Manifold: Define settings

1. In the Manual window, click the Valve icon.

press to zoom
1/4
 
 

RELATED PRODUCTS

ExiGo syringe pump with automatic syring

ExiGo Syringe Pump

UniGo pump with pump manifold.jpg

UniGo Pressure Pump

Tygon Tubing Roll.jpg

Tubing & Connectors

Cell Culture Bottle.jpg

Sample Reservoirs

 
 

DEMONSTRATIONS & HOW TO...

 

TRAINING VIDEOS